6
3. Other Alarm Visual and Audible Indicators
(1) Requires additional devices and/or permissions in app to enable these features.
Operational Mode Visual Indications Audible Indications Action/Note:
Normal (standby)
AC power: Green LED on continuously during
light conditions, or blink every 60 sec during dark
conditions.
DC power: Green LED blink approx every 60 sec.
Test (button press when no
alarm condition is present,
and the device is online and
connected to Wi-Fi, or if the
device was never connected
to Wi-Fi, or if the device was
reset and removed from a Wi-Fi
network.)
• 4 patterns of Red/Amber/Green.
• Test: Red LED blinks in time with alarm
pattern.
• Green LED fade on/off at test complete
• Button press sound
• Voice: "Testing, this is very loud.
Press now to cancel test. 5, 4, 3, 2, 1."
• 3 long beeps, Voice "Fire!",
3 long beeps, 4 quick beeps, Voice
"Warning, Carbon Monoxide," 4
quick beeps, Voice "Test Complete,"
Power on/reset sound.
• Voice "Test Canceled" if button
pushed before test sequence begins.
Perform button press once a week
to verify proper alarm operation
* Push/release button before the
countdown ends to cancel test.
Test (button press when no
alarm condition is present, and
the device is disconnected from
Wi-Fi)
None Voice "Not Connected" after button
push.
.
Take appropriate action to restore
Wi-Fi connection.
Smoke or CO Alarm Memory
(unit has experienced a smoke
or CO alarm event within the
last hour)
Red and Amber LED alternate on 1 sec,
every 10 sec.
After button push, voice "Smoke
previously detected" or "Carbon
Monoxide previously detected" only on
the initiating alarm unit.
Push button to clear Alarm
Memory. NOTE: standard test
sequence will follow. (Push/release
button again to cancel test).
Smoke Alarm Hush Mode,
(SMART HUSH®
CONTROL)
Red LED blinks every 2 sec. After button push, voice "Hush Mode
Activated." Smoke alarm pattern
stops.
(If there is too much smoke to allow
Hush: Voice "Too Much Smoke, Alarm
cannot be Hushed" Smoke alarm
pattern continues.)
This feature is to be used only
when a known alarm condition,
such as smoke from cooking,
activates the alarm.
CO alarm reset None After button push: CO alarm pattern
stops.
Unit is confirming if CO is present
or if it experienced a nuisance
situation. Re-alarm means danger.
Move to fresh air and call 911.
Smoke Alarm Hush Mode
Canceled
None Voice "Hush Mode Canceled." When smoke levels drop below the
alarm threshold, the voice message
will occur .
Initiating Alarm,
(Multiple alarms in an
interconnected system)
Green LED blinks once per sec indicating
that this is the unit initiating the alarm in an
interconnected, multiple alarm, system.
Unit in either Smoke or CO alarm
mode.
During alarm, the initiating alarm
red blink will be interrupted by a
green blink.
Weather & Intruder Alert
(1)
Red LED flashes every sec. One long beep, 5 sec pause, Voice:
“Weather emergency in vicinity” OR
one long beep every other sec, voice
every 10 sec “Intruder detected.”
Take appropriate precautions.